Ieee 693 free download

Seismic qualification and time history shaketable testing. Seismic considerations of circuit breakers willie freeman, ieee 693 working group abb inc, mt. General requirements for liquidimmersed distribution, power, and regulating transformers. Ieee std 6932005, recommended practice for seismic design of. The current version of the standard ieee, 693 allows seismic qualifications testing when an actual support structure is not yet known, by imposing an amplification factor to required response spectra. Ieee 344 ieee recommended practice for the seismic qualification of. Ieee recommended practice for seismic design of substations. Read online ieee recommended practice for the seismic design of. Report ieee std 693 2004 recommended practice for seismic design of. Ieee recommended practice for seismic design of substations ieee on. Find the most uptodate version of ieee 693 at engineering360. Ieee standard method for measuring the effectiveness of. Proposed for new ieee 693 pacific earthquake engineering. Ieee 693 recommended practice for seismic design of substations mainly applied in the american continent and iec 62271 family of standards applied in the rest of.

Ieee std 693 is designed as an integrated set of requirements for the seismic qualification of electrical power. Ieee std 693 2018 revision of ieee std 693 2005 published. Changes in this revision of isoiec 12207 were developed in conjunction with a corresponding revision of isoiec 15288. Ieee std 693 2004 recommended practice for seismic design of. What structural engineers should know about substation rigid bus design. Test requirements for seismic qualification of substation. Ieee std 693 2004 recommended practice for seismic. Ieee std 693 2004 recommended practice for seismic design of substations. Pdf seismic qualification of high voltage electric supply. Seismic qualification test protocols, standards and.

The first support is defined as the pedestal and support structure for a free. Ieee std 693tm is designed as an integrated set of requirements for the seismic qualification of electrical power equipment. The ieee 69305 battery racks produced by passoni alpha are hereby certified for compliance with the following code. The purpose of these revisions is to better align the two international standards to. Ieee 6932018 is the ieee recommended practice for seismic design of substations in ancient greece, an earthquake was said to occur when poseidon was in a bad mood. Design recommendations consist of seismic criteria, qualification methods and levels, structural capacities, performance requirements for equipment operation. Seismic qualification test protocols, standards and methodology chris stone, trac global limited. Ieee 693 2018 ieee recommended practice for seismic.

The existence of an ieee standard does not imply that. Users should use ieee std 693 without modification or removal of any requirement, except as allowed herein. Ieee recommended practice for the seismic design of. Ieee std 693 tm is designed as an integrated set of requirements for the seismic qualification of electrical power equipment. According to ieee 693, if the test was done properly, the unit is seismically qualified to be mounted on any support. Whether youve loved the book or not, if you give your honest and detailed thoughts then people will find new books that are right for them. Circuit breaker, response spectrum, ieee std 693, seismic. Ieee websites place cookies on your device to give you the best user experience. Ieee 6932005 ieee recommended practices for seismic design of substations. Ieee 693 2018 ieee recommended practice for seismic design of substations. Ieee std 1422007 revision of ieee std 1421991 ieee.

Users should use ieee std 693 without modification or removal of any. Customers who purchased ieee 693 also purchased ieee c57. Ieee membership offers access to technical innovation, cuttingedge information, networking opportunities, and exclusive member benefits. Access and download executable and other types of files related to specific ieee standards and amendments. Ieee std 1001996, ieee standard dictionary of electrical and electronic terms, 6th ed. Other readers will always be interested in your opinion of the books youve read. Ieee 693 covers seismic qualification of battery racks, transformers, switchgear and other products and equipment for substations. Members support ieees mission to advance technology. Ipr of standards developing organizations sdos, we have implemented a security policy that utilizes a free adobe acrobat plugin from.

A29a29m99e1 standard specification for steel bars, carbon and alloy, hotwrought and coldfinished, general requirements for. What structural engineers should know about substation. Ieee std 693tm is designed as an integrated set of requirements for the seismic qualification of electrical. The standard details the requirements for qualification by analysis and shake table testing. Recommended practice for seismic design of substations. Pdf overview of major seismic standards for high voltage. Committee members discussed potential revisions to the ieee 693 standard at a meeting in portland.

However, according to ieee 693, it is the end users responsibility to ensure their support. Instructions on how to include this recommended practice in specifications are provided. Ppt seismic considerations powerpoint presentation. Ieee 693 strongly recommends that equipment should be qualified on the support structure that will be used at the final substation. Some may be different iterations based on the year of publication, please be sure you are accessing the proper file needed based on the standard purchased. Ieee aims to improve seismic design of power substations. Ieee guide for direct lightning stroke shielding of substations 1. Ieee 693 recommended practice a common standard within the seismic certification realm is ieee 693.

Ieee std 9981996, ieee guide for direct lightning stroke. Ieee 69305 recommended practice for seismic design of substations by. The direct way to get started with applying ieee 693 is to go first to figure 1 in the standard. Ieee std 6932018 revision of ieee std 6932005 published.

Ieee std 693 is designed as an integrated set of requirements for the seismic qualification of electrical power equipment. The existence of an ieee standard does not imply that there are no other ways to. Ieee 6931997 ieee recommended practices for seismic design of substations. Ieee 6932005 ieee recommended practices for seismic. Seismic tests in accordance with ieee 6932005 were performed on an. The paper describes the development of ieee 693, the goals of the working group. The code can be downloaded from the peer website presenting all. Ieee 691 guide for transmission structure foundation. Ieee 693 is a document that primarily directs the design and qualification of equipment installed in substations and its ability to withstand a seismic event. The ieee693 recommended practice for seismic design of substations working group was formed in part to address the seismic vulnerability. Ieee 693 recommended practice for seismic design of. Seismic considerations of circuit breakers abb group.

Immediate download just after checkout lowest prices online customer satisfaction guaranteed. Download pdf download citation view references email request permissions export to collabratec alerts abstract. Ieee recommended practice for the seismic design of substations. Delivering full text access to the worlds highest quality technical literature in engineering and technology. This study was undertaken to address new developments in ieee p693d16 ieee693 wg 2017.

Ieee p751 draft guide for wood structures used for overhead electric transmission lines published by ieee on may 7, 2018 this guide consolidates useful information, methods, and reference materials. Ieee and its members inspire a global community to innovate for a better tomorrow through highly cited publications, conferences, technology standards, and professional and educational activities. The following information is related to specific ieee standards and amendments and can be downloaded at no cost. One of its recommended shaker test methods for power equipment is to use a sine beat. In contrast, iec 61463 bushings seismic qualification 2 is an iec. The current version of the standard ieee, 693 allows.

Ieee 6932005 seismic qualification testing of hubbell. Download ieee recommended practice for the seismic design of. The recommended practice contains recommendations for the seismic design of substation buildings, structures, and. Visit the peer publications page to download a free color pdf of the document. Pdf test requirements for seismic qualification of.

803 1369 1167 1210 1100 342 804 1429 1543 1041 990 953 728 1490 264 454 789 65 682 205 996 325 1183 908 629 176 563 1393 1034 1065 1322